• sns01
  • sns03
  • sns02

Andedan kay la vakyòm Awondisman brekè

  • ZN85-40.5 Series Indoor High Voltage Vacuum Circuit Breaker

    ZN85-40.5 Seri Andedan kay la segondè Voltage vakyòm Awondisman brekè

    ZN85-40.5 andedan kay la HV sikwi brekè se yon 3-faz AC 50Hz 40.5kV ekipman switch andedan kay la. ♦ Fason enstalasyon: kalite retrè; ♦ Mekanis opere: mekanis opere sezon prentan; ♦ Kalite poto: poto reyini, poto entegre; ♦ Aplikasyon: aparèy KYN61-40.5. ♦ Ploge Segondè: 58pins, 64pins. Kondisyon anviwònman ♦ Tanperati anbyen: -15r ~ + 40r ; ♦ Altitid: <1000m; ♦ Imidite relatif: mwayèn chak jou <95%, mwayèn chak mwa <90% ; ♦ Entansite tranbleman tè: <8 nivo; ♦ Pla ...
  • VSG-24 Series Indoor High Voltage Vacuum Circuit Breaker

    VSG-24 Seri Andedan kay la segondè Voltage vakyòm Awondisman brekè

    VSG-24 HV andedan kay la vakyòm brekè se yon 3-faz AC 50Hz 24kV ekipman switch andedan kay la ♦ Fonksyònman mekanis: prentan fonksyònman mekanis; ♦ Kalite poto: poto reyini : poto entegre; ♦ faz-a-faz distans: 275mm; Kondisyon anviwònman ♦ Tanperati anbyen: -15 ° C ° + 40 ° C; ♦ Altitid: <1000m; ♦ Imidite relatif: mwayèn chak jou <95%, mwayèn chak mwa <90% ; ♦ Entansite tranbleman tè: <8 nivo; ♦ Andwa san dife, danje eksplozyon, sal grav, korozyon chimik, kòm wel ...
  • VSG-12 Series Indoor High Voltage Vacuum Circuit Breaker

    VSG-12 Seri Andedan kay la High Voltage Vacuum Awondisman brekè

    VSG-12 HV andedan kay la vakyòm sikwi brekè se yon 3-faz AC 50Hz 12kV ekipman switch andedan kay la. ♦ Fason enstalasyon: kalite retrè, kalite fiks; ♦ Mekanis opere: mekanis opere sezon prentan; ♦ Kalite poto: poto reyini, poto entegre; ♦ Faz-a-faz distans: 150mm, 210mm, 275mm; Kondisyon anviwònman ♦ Tanperati anbyen: -15r ~ + 40r ; ♦ Altitid: <1000m; ♦ Imidite relatif: mwayèn chak jou <95%, mwayèn chak mwa <90% ; ♦ Entansite tranbleman tè: <8 nivo; ♦ Andwa san dife, ...
  • VS1-24 Series Indoor High Voltage Vacuum Circuit Breaker

    VS1-24 Seri Andedan kay la High Voltage Vacuum Awondisman brekè

    VS1-24 andedan kay la HV vakyòm sikwi brekè se yon 3-faz AC 50Hz 24kV ekipman switch andedan kay la ♦ Enstalasyon fason: kalite retrè, kalite fiks, bò monte kalite; ♦ Mekanis fonksyònman: mekanis fonksyònman prentan ak mekanis pèmanan fonksyònman mayetik; ♦ Kalite poto: poto reyini, poto entegre; ♦ Aplikasyon: sw.tchgear KYN28-24, XGN-24. ♦ Ploge Segondè: 58pins, 64pins. Pwodwi Standards ♦ IEC62271-100 High Voltage switchgear ak Controlgear Pati 100: AC Awondisman-kasè ♦ GB1984 High Vol ...
  • VS1-12 Series Indoor High Voltage Vacuum Circuit Breaker

    VS1-12 Seri Andedan kay la segondè Voltage vakyòm Awondisman brekè

    VS1-12 andedan kay la HV sikwi brekè se yon 3-faz AC 50Hz 12kV ekipman switch andedan kay la. ♦ Fason enstalasyon: kalite retrè, kalite fiks, bò monte kalite; ♦ Mekanis opere: mekanis Rating sezon prentan, mekanis pèmanan opere mayetik; ♦ Kalite poto: poto reyini, poto entegre; ♦ Aplikasyon: aparèy KYN28-12, XGN-12. ♦ Ploge Segondè: 58pins, 64pins. Pwodwi Standards ♦ IEC62271-100 High Voltage switchgear ak Controlgear Pati 100: AC Awondisman-kasè ♦ GB1984 High Vol ...
  • ZN12-12/40.5 Series Indoor High Voltage Vacuum Circuit Breaker

    ZN12-12 / 40.5 Seri Andedan kay la segondè Voltage vakyòm Awondisman brekè

    ZN12-12 / 40.5 andedan kay la HV sikwi brekè se yon 3-faz AC 50Hz 12kV / 40.5KV ekipman switch andedan kay la. ♦ Fason enstalasyon: kalite retrè, kalite fiks; ♦ Mekanis fonksyònman: mekanis Rating sezon prentan; ♦ Aplikasyon: switchgear GBC-35, JYN1-35. Kondisyon anviwònman ♦ Tanperati anbyen: -25 ^ ~ + 40 ^; ♦ Altitid: <1000m; ♦ Imidite relatif: mwayèn chak jou <95%, mwayèn chak mwa <90% ; ♦ Entansite tranbleman tè: <8 nivo; ♦ Andwa san dife, danje eksplozyon, sal grav, ...
  • VSG-24 Series Indoor High Voltage Vacuum Circuit Breaker

    VSG-24 Seri Andedan kay la segondè Voltage vakyòm Awondisman brekè

    VSG-24 seri lateral kalite vòltaj segondè vòltaj brekè sikwi aplike nan twa-faz AC 50 (60) Hz 24KV sistèm pouvwa, ki ka itilize pou chanje aktyèl chaj, Surcharge aktyèl ak aktyèl fay nan endistriyèl ak min antrepriz, plant pouvwa, poste transfòmatè ak apwopriye pou okazyon operasyon souvan Li tou lajman aplike nan pwojè, tankou plant pouvwa, sistèm pouvwa, petrifaction, metaliji, métro, avyon, bilding, elatriye Kondisyon anviwònman ♦ Tanperati anbyen: ...